{"id":1741,"date":"2022-12-19T19:39:32","date_gmt":"2022-12-19T12:39:32","guid":{"rendered":"https:\/\/www.futurexray.com\/%e0%b8%9b%e0%b8%a3%e0%b8%b0%e0%b8%95%e0%b8%b9%e0%b8%9b%e0%b9%89%e0%b8%ad%e0%b8%87%e0%b8%81%e0%b8%b1%e0%b8%99%e0%b8%a3%e0%b8%b1%e0%b8%87%e0%b8%aa%e0%b8%b5%e0%b9%80%e0%b8%ad%e0%b8%81%e0%b8%8b%e0%b9%80-2\/"},"modified":"2026-01-16T14:51:02","modified_gmt":"2026-01-16T07:51:02","slug":"automatic-x-ray-radiation-protection-door","status":"publish","type":"page","link":"https:\/\/www.futurexray.com\/en\/automatic-x-ray-radiation-protection-door\/","title":{"rendered":"Automatic X-ray Radiation Protection Door"},"content":{"rendered":"\n\n\n<style>\ntable tr:nth-child(odd) {\n    background: #f9f9f9;\n}\ntable tr {\n    height: 40px;\n    line-height: 40px;\n}\ntable td {\n    text-align: center;\n    border: 1px solid #eee;\n}\n\/\/tr:hover{\nbackground: #ffcc00 !important;\n}\n<\/style>\n\n\t<section class=\"section\" id=\"section_536920454\">\n\t\t<div class=\"bg section-bg fill bg-fill  bg-loaded\" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n\n<div class=\"row\"  id=\"row-51798015\">\n\n\n\t<div id=\"col-2077798862\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n<div class=\"container section-title-container\" ><h3 class=\"section-title section-title-normal\"><b><\/b><span class=\"section-title-main\" style=\"color:rgb(255, 204, 0);\">Automatic X-ray Radiation Protection Door<\/span><b><\/b><\/h3><\/div>\n\n<table>\n<tbody>\n<tr>\n<td style=\"background: #ffcc00; color: #222222;\">DOOR TYPE<\/td>\n<td style=\"background: #ffcc00; color: #222222;\">AUTOMETIC<\/td>\n<td style=\"background: #ffcc00; color: #222222;\">Weight (kg)<\/td>\n<td style=\"background: #ffcc00; color: #222222;\">Door Panel<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\n<p>Single Sliding Door<\/p>\n<p><img data-dominant-color=\"6a7d86\" data-has-transparency=\"true\" style=\"--dominant-color: #6a7d86;\" decoding=\"async\" class=\"has-transparency alignnone size-full wp-image-823\" src=\"https:\/\/www.futurexray.com\/wp-content\/uploads\/2022\/12\/door-type.png\" alt=\"\" width=\"148\" height=\"129\" \/><\/p>\n<\/td>\n<td rowspan=\"2\">\u25cf<\/td>\n<td rowspan=\"2\">180 \u2013 500 kg<\/td>\n<td>X-ray Radiation Shielding Door Panel<\/td>\n<\/tr>\n<tr>\n<td>Airtight Door Panel<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Additional accessories for automatic doors to enhance functionality and performance, such as <strong>remote controls, wireless push buttons, and various sensor options<\/strong>.<\/p>\n<div class=\"row\"  id=\"row-461568560\">\n\n\n\t<div id=\"col-656356701\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\t<div class=\"img has-hover x md-x lg-x y md-y lg-y\" id=\"image_612550335\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/www.futurexray.com\/wp-content\/uploads\/2023\/03\/auto-door-1-2-jpg.webp\" class=\"attachment-large size-large not-transparent\" alt=\"\" srcset=\"https:\/\/www.futurexray.com\/wp-content\/uploads\/2023\/03\/auto-door-1-2-jpg.webp 500w, https:\/\/www.futurexray.com\/wp-content\/uploads\/2023\/03\/auto-door-1-2-300x300.webp 300w, https:\/\/www.futurexray.com\/wp-content\/uploads\/2023\/03\/auto-door-1-2-150x150.webp 150w\" sizes=\"(max-width: 500px) 100vw, 500px\" data-has-transparency=\"false\" data-dominant-color=\"b6b3ad\" style=\"--dominant-color: #b6b3ad;\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_612550335 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1046898361\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n<div class=\"container section-title-container\" ><h3 class=\"section-title section-title-normal\"><b><\/b><span class=\"section-title-main\" style=\"color:rgb(255, 204, 0);\">Automatic Lead Door System \u2013 Includes<\/span><b><\/b><\/h3><\/div>\n\n<ol>\n<li><strong>Rail Track<\/strong> \u2013 Track rail for the automatic system (Slim Type)<\/li>\n<li><strong>Drive Motor (100 W)<\/strong> \u2013 High-torque motor suitable for lead-lined X-ray doors, supporting door weights up to <strong>150\u2013200 kg<\/strong><\/li>\n<li><strong>Controller (Control Set)<\/strong> \u2013 Operating control system for the lead door, controlling door opening\/closing with a <strong>microcontroller system<\/strong>. Offers various functions and safety features, and allows setting operating parameters such as <strong>opening\/closing speed<\/strong><\/li>\n<li><strong>Timing Belt<\/strong> \u2013 High durability belt to extend the service life of the lead door system (high-quality belt, imported from <strong>Italy<\/strong>)<\/li>\n<li><strong>Hanger<\/strong> \u2013 High-quality hanger made from <strong>Nylon 6<\/strong>, supporting weights up to <strong>200 kg<\/strong>, used as the hanging component for the X-ray radiation protection door<\/li>\n<li><strong>Idle Pulley<\/strong><\/li>\n<li><strong>Sensor<\/strong> \u2013 Detects and commands the opening\/closing operation of the X-ray radiation protection door<\/li>\n<li><strong>Safety Beam<\/strong> \u2013 Anti-crush \/ safety protection system for the door<\/li>\n<\/ol>\n<div class=\"container section-title-container\" ><h3 class=\"section-title section-title-normal\"><b><\/b><span class=\"section-title-main\" style=\"color:rgb(255, 204, 0);\">Customers Can Choose Door Types<\/span><b><\/b><\/h3><\/div>\n\n<ol>\n<li><strong>Sliding X-ray radiation protection door<\/strong><\/li>\n<li><strong>Swing X-ray radiation protection door<\/strong><\/li>\n<li><strong>Automatic X-ray radiation protection door<\/strong><\/li>\n<\/ol>\n<p>Automatic X-ray radiation protection doors can be controlled for opening and closing using modern technology. The system uses a belt-driven motor imported from <strong>Germany<\/strong>, certified for quality and standard compliance.<\/p>\n<ul>\n<li><strong>Automatic Sliding Lead Door (Automatic Slide Door)<\/strong><\/li>\n<li><strong>Automatic Telescopic Sliding Lead Door (Telescopic Slide Door)<\/strong><\/li>\n<li><strong>Airtight Lead Door System (Hermetic Door)<\/strong><\/li>\n<\/ul>\n<div class=\"container section-title-container\" ><h3 class=\"section-title section-title-normal\"><b><\/b><span class=\"section-title-main\" style=\"color:rgb(255, 204, 0);\">Customers Can Select Lead Sheet Thickness Suitable for the Installation Area<\/span><b><\/b><\/h3><\/div>\n\n<table>\n<tbody>\n<tr>\n<td style=\"background: #ffcc00; color: #222222;\" colspan=\"3\">X-ray Room Type<\/td>\n<td style=\"background: #ffcc00; color: #222222;\" colspan=\"5\">Lead Sheet Thickness Inside Door Panel<\/td>\n<td style=\"background: #ffcc00; color: #222222;\" colspan=\"4\">SSDLR Test Report<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Dental X-ray<\/td>\n<td colspan=\"5\" rowspan=\"3\">1.0 mm<\/td>\n<td colspan=\"4\" rowspan=\"3\">458000400<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Mammogram<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Bone Density<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">General x-ray<\/td>\n<td colspan=\"5\">1.5 mm<\/td>\n<td colspan=\"4\">46201022021<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">CT Scan<\/td>\n<td colspan=\"5\" rowspan=\"6\">2\u20133 mm<\/td>\n<td colspan=\"4\">0463167380 (2.0 mm)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Fluoroscopy<\/td>\n<td colspan=\"4\" rowspan=\"3\">0463346807 (2.5 mm)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Cath Lab<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Hybrid Operating Room<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Intervention Room<\/td>\n<td colspan=\"4\" rowspan=\"2\">04970003851 (3.0 mm)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">ERCP Room<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n<\/div>\n\n\t\t<\/div>\n\n\t\t\n<style>\n#section_536920454 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n#section_536920454 .ux-shape-divider--top svg {\n  height: 150px;\n  --divider-top-width: 100%;\n}\n#section_536920454 .ux-shape-divider--bottom svg {\n  height: 150px;\n  --divider-width: 100%;\n}\n<\/style>\n\t<\/section>\n\t\n\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"footnotes":""},"class_list":["post-1741","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v20.12 (Yoast SEO v21.5) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Automatic X-ray Radiation Protection Door - Future Xray<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.futurexray.com\/en\/automatic-x-ray-radiation-protection-door\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Automatic X-ray Radiation Protection Door\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.futurexray.com\/en\/automatic-x-ray-radiation-protection-door\/\" \/>\n<meta property=\"og:site_name\" content=\"Future Xray\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-16T07:51:02+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.futurexray.com\/wp-content\/uploads\/2022\/12\/door-type.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.futurexray.com\/en\/automatic-x-ray-radiation-protection-door\/\",\"url\":\"https:\/\/www.futurexray.com\/en\/automatic-x-ray-radiation-protection-door\/\",\"name\":\"Automatic X-ray Radiation Protection Door - Future Xray\",\"isPartOf\":{\"@id\":\"https:\/\/www.futurexray.com\/en\/#website\"},\"datePublished\":\"2022-12-19T12:39:32+00:00\",\"dateModified\":\"2026-01-16T07:51:02+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.futurexray.com\/en\/automatic-x-ray-radiation-protection-door\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.futurexray.com\/en\/automatic-x-ray-radiation-protection-door\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.futurexray.com\/en\/automatic-x-ray-radiation-protection-door\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.futurexray.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Automatic X-ray Radiation Protection Door\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.futurexray.com\/en\/#website\",\"url\":\"https:\/\/www.futurexray.com\/en\/\",\"name\":\"Future Xray\",\"description\":\"\u0e2d\u0e38\u0e1b\u0e01\u0e23\u0e13\u0e4c\u0e1b\u0e49\u0e2d\u0e07\u0e01\u0e31\u0e19 \u0e23\u0e31\u0e07\u0e2a\u0e35\u0e40\u0e2d\u0e01\u0e0b\u0e40\u0e23\u0e22\u0e4c \u0e41\u0e1c\u0e48\u0e19\u0e15\u0e30\u0e01\u0e31\u0e48\u0e27\u0e01\u0e31\u0e19\u0e23\u0e31\u0e07\u0e2a\u0e35\u0e40\u0e2d\u0e01\u0e0b\u0e40\u0e23\u0e22\u0e4c  \u0e01\u0e23\u0e30\u0e08\u0e01\u0e01\u0e31\u0e19\u0e23\u0e31\u0e07\u0e2a\u0e35  \u0e1b\u0e23\u0e30\u0e15\u0e39\u0e01\u0e31\u0e19\u0e23\u0e31\u0e07\u0e2a\u0e35 \u0e1c\u0e19\u0e31\u0e07\u0e15\u0e30\u0e01\u0e31\u0e48\u0e27\u0e01\u0e31\u0e19\u0e23\u0e31\u0e07\u0e2a\u0e35\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.futurexray.com\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Automatic X-ray Radiation Protection Door - Future Xray","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.futurexray.com\/en\/automatic-x-ray-radiation-protection-door\/","og_locale":"en_US","og_type":"article","og_title":"Automatic X-ray Radiation Protection Door","og_url":"https:\/\/www.futurexray.com\/en\/automatic-x-ray-radiation-protection-door\/","og_site_name":"Future Xray","article_modified_time":"2026-01-16T07:51:02+00:00","og_image":[{"url":"https:\/\/www.futurexray.com\/wp-content\/uploads\/2022\/12\/door-type.png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.futurexray.com\/en\/automatic-x-ray-radiation-protection-door\/","url":"https:\/\/www.futurexray.com\/en\/automatic-x-ray-radiation-protection-door\/","name":"Automatic X-ray Radiation Protection Door - Future Xray","isPartOf":{"@id":"https:\/\/www.futurexray.com\/en\/#website"},"datePublished":"2022-12-19T12:39:32+00:00","dateModified":"2026-01-16T07:51:02+00:00","breadcrumb":{"@id":"https:\/\/www.futurexray.com\/en\/automatic-x-ray-radiation-protection-door\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.futurexray.com\/en\/automatic-x-ray-radiation-protection-door\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.futurexray.com\/en\/automatic-x-ray-radiation-protection-door\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.futurexray.com\/en\/"},{"@type":"ListItem","position":2,"name":"Automatic X-ray Radiation Protection Door"}]},{"@type":"WebSite","@id":"https:\/\/www.futurexray.com\/en\/#website","url":"https:\/\/www.futurexray.com\/en\/","name":"Future Xray","description":"\u0e2d\u0e38\u0e1b\u0e01\u0e23\u0e13\u0e4c\u0e1b\u0e49\u0e2d\u0e07\u0e01\u0e31\u0e19 \u0e23\u0e31\u0e07\u0e2a\u0e35\u0e40\u0e2d\u0e01\u0e0b\u0e40\u0e23\u0e22\u0e4c \u0e41\u0e1c\u0e48\u0e19\u0e15\u0e30\u0e01\u0e31\u0e48\u0e27\u0e01\u0e31\u0e19\u0e23\u0e31\u0e07\u0e2a\u0e35\u0e40\u0e2d\u0e01\u0e0b\u0e40\u0e23\u0e22\u0e4c  \u0e01\u0e23\u0e30\u0e08\u0e01\u0e01\u0e31\u0e19\u0e23\u0e31\u0e07\u0e2a\u0e35  \u0e1b\u0e23\u0e30\u0e15\u0e39\u0e01\u0e31\u0e19\u0e23\u0e31\u0e07\u0e2a\u0e35 \u0e1c\u0e19\u0e31\u0e07\u0e15\u0e30\u0e01\u0e31\u0e48\u0e27\u0e01\u0e31\u0e19\u0e23\u0e31\u0e07\u0e2a\u0e35","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.futurexray.com\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.futurexray.com\/en\/wp-json\/wp\/v2\/pages\/1741","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.futurexray.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.futurexray.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.futurexray.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.futurexray.com\/en\/wp-json\/wp\/v2\/comments?post=1741"}],"version-history":[{"count":5,"href":"https:\/\/www.futurexray.com\/en\/wp-json\/wp\/v2\/pages\/1741\/revisions"}],"predecessor-version":[{"id":1879,"href":"https:\/\/www.futurexray.com\/en\/wp-json\/wp\/v2\/pages\/1741\/revisions\/1879"}],"wp:attachment":[{"href":"https:\/\/www.futurexray.com\/en\/wp-json\/wp\/v2\/media?parent=1741"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}